Hi Benedikt!
You can just set the n_events property of the recorder to 0. That will clear the stored
events when recording to memory or just reset the counter when recording to ASCII. The
relevant documentation (for master, aka NEST 3.0) is in the guide on recording from
simulations<https://nest-simulator.readthedocs.io/en/latest/guides/recording_from_simulations.html>.
Cheers,
Jochen!
On 02.12.20 17:53, feldotto wrote:
Dear all,
I am running a large simulation where I need to evaluate the spike frequency of large
populations in several elapsed time frames. In order to keep this procedure efficient and
memory efficient, is it possible to reset the spikeDetector (delete all events)?
Thanks in advance!
Best,
Benedikt
_______________________________________________
NEST Users mailing list --
users@nest-simulator.org<mailto:users@nest-simulator.org>
To unsubscribe send an email to
users-leave@nest-simulator.org<mailto:users-leave@nest-simulator.org>
--
Dr. Jochen Martin Eppler
Phone: +49(2461)61-96653
----------------------------------
Simulation Laboratory Neuroscience
Jülich Supercomputing Centre
Institute for Advanced Simulation
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------
Forschungszentrum Juelich GmbH
52425 Juelich
Sitz der Gesellschaft: Juelich
Eingetragen im Handelsregister des Amtsgerichts Dueren Nr. HR B 3498
Vorsitzender des Aufsichtsrats: MinDir Volker Rieke
Geschaeftsfuehrung: Prof. Dr.-Ing. Wolfgang Marquardt (Vorsitzender),
Karsten Beneke (stellv. Vorsitzender), Prof. Dr.-Ing. Harald Bolt
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------