Hi Atiyeh,
If you mark the "I_syn_inh" and "I_syn_exc" inline expressions as
"recordable", they can be recorded by the NEST multimeter. Just put the keyword
"recordable" in front of "inline". See here for documentation on the
feature:
Hope this helps!
Kind regards,
Charl
On Fri, Nov 10, 2023, at 12:06, atiye nejadebrahim wrote:
Dear Charl,
yes, I add another Ion channel to the current model named *hh_psc_alpha1.nestml * and
make it conductance based.enclosed you can find it.
thanks,
Best,
Atiyeh
On Friday, November 10, 2023 at 11:59:07 AM GMT+1, Charl Linssen
<nest-users(a)turingbirds.com> wrote:
Dear Atiyeh,
Could you tell us which specific neuron model(s) you are using? Are you using NESTML for
the models?
Cheers,
Charl
On Fri, Nov 10, 2023, at 11:55, atiye nejadebrahim wrote:
Hello all,
I need to record I_sys from the neurons of network, but when I use *.recordables* for my
neuron defined,* I_syn* isn't included in recording. can you help me how can I make
I_sys recordable?
Thanks for your help.
Best,
Atiyeh
_______________________________________________
NEST Users mailing list -- users(a)nest-simulator.org
To unsubscribe send an email to users-leave(a)nest-simulator.org
_______________________________________________
NEST Users mailing list -- users(a)nest-simulator.org
To unsubscribe send an email to users-leave(a)nest-simulator.org
_______________________________________________
NEST Users mailing list -- users(a)nest-simulator.org
To unsubscribe send an email to users-leave(a)nest-simulator.org
*Attachments:*
• hh_psc_alpha2.nestml